Digital sterilization logs for dental offices

Last reviewed November 7, 2026  ·  2 sources

Short answer

ComplyDay replaces the paper autoclave log. Staff log each cycle, spore test and Bowie-Dick test from a phone in a few taps, and a failed test alerts the office manager right away.

Reminders go out for the weekly spore test, and every entry shows who logged it and when. The logs print in your inspection binder.

What you can log

LogWhat staff recordCDC recommendation
Sterilizer cyclesCycle number, temperature and time, load contents, chemical indicator result, who checked itCheck mechanical readings every load and a chemical indicator in every package
Spore testsSterilizer, date, strip lot number, result, control resultAt least weekly for each sterilizer, and every load with an implant
Bowie-Dick testsSterilizer, date, resultFor dynamic air removal (prevacuum) sterilizers, as the sterilizer manufacturer recommends
MaintenanceCleaning, gasket checks, water changes, service visitsFollow the manufacturer's instructions

For example, a cycle entry reads "Cycle 1042, 134 °C for 4 minutes, pouches, logged by Maria Lopez at 8:12."

When a test fails

A failed spore or Bowie-Dick test sends an urgent email to every owner and admin right away, usually the dentist and the office manager. The alert lists the steps CDC recommends after a positive spore test:

  1. Take the sterilizer out of service.
  2. Review sterilization procedures: loading, packaging and the cycle used.
  3. Retest the sterilizer with spore tests and chemical indicators.
  4. If the retest is negative, put the sterilizer back in use.
  5. If the retest is positive, recall and reprocess the items processed since the last negative test, and have the sterilizer checked before use.

The spore testing guide explains each step.

Reminders

Set the weekly spore test day once, for example every Monday at 8:00, and ComplyDay reminds the person responsible. Missed tests show up on the dashboard before anyone else notices.

Records that stay put

Paper logs get wet, lost and filled in late. Each ComplyDay entry is saved with the time and the person who made it. Records stay while you subscribe, and you can download them at any time. Keep them as long as your state requires.

If you'd rather stay on paper, the free autoclave log sheet has a cycle log, a spore test log and a maintenance log.

Price

Solo logs two sterilizers for $66 a month paid yearly. Practice logs every sterilizer in your office for $125 a month paid yearly. Both include training, written plans and reminders. See the plans.

Questions

What does a dental sterilization log need to record?

CDC recommends checking the mechanical readings (time, temperature and pressure) for every load, using a chemical indicator in every package, and running a spore test at least weekly on each sterilizer and with every load that contains an implant. Your log should show those results, the date, the load contents and who checked it.

Is a digital sterilization log accepted?

Federal rules don’t require paper. CDC says sterilization records should be kept in a way that meets your state and local rules. If your state dental board has a specific format or retention period, follow it. ComplyDay keeps the date, time and person on every entry.

What happens when a spore test fails?

Every owner and admin, usually the dentist and the office manager, gets an urgent email right away. CDC’s steps are to take the sterilizer out of service, review the loading and operation, retest, and if the retest fails, recall and reprocess items from the suspect loads.

Can we still use paper logs?

Yes. Our free autoclave log sheet works for any office. ComplyDay is the faster way: entries take a tap, reminders go out for the weekly spore test, and the logs print in the inspection binder.